-40%

IFM SU7001 Ultrasonic Flow Meter/Sensor for Water/Oils

$ 264

Availability: 100 in stock
  • Condition: Was pulled from a working system today.
  • Brand: Efector
  • All returns accepted: ReturnsNotAccepted
  • MPN: SU7001
  • Model: SU7001

    Description

    This was pulled from a working system today. Please see specs.
    Ultrasonic flow meter
    Quick disconnect
    Process connection: G¾ flat seal
    Function programmable
    Totalizer function
    2 outputs
    OUT1 = flow monitoring (binary), flow rate meter (pulse), preset meter (binary)
    OUT2 = flow monitoring or temperature monitoring (analog or binary)
    Input for counter reset
    Measuring range
    0...13.22 gpm
    14...176 °F
    Maximum permissible flow rate
    15.86 gpm (951 gph)
    connection to pipe by means of an adapter
    Application
    Application
    Liquids of the fluid group 2 according to the Pressure Equipment Directive (PED):
    water, glycol solutions, oils
    (low-viscosity oils with viscosity 7...40 mm²/s at 40°C;
    high-viscosity oils with viscosity 30...68 mm²/s at 40°C)
    Pressure rating [psi]
    232
    Medium temperature [°F]
    14...176
    Electrical data
    Electrical design
    DC PNP/NPN
    Operating voltage [V]
    19...30 DC ¹)
    Current consumption [mA]
    100
    Insulation resistance [MΩ]
    > 100 (500 V DC)
    Protection class
    III
    Reverse polarity protection
    yes
    Outputs
    Output function
    OUT1: normally open / closed programmable or pulse
    OUT2: normally open / closed programmable or analog (4...20 mA / 0...10 V, scaleable)
    Current rating [mA]
    2 x 250
    Voltage drop [V]
    < 2
    Short-circuit protection
    yes (non-latching)
    Overload protection
    yes
    Analog output
    4...20 mA; 0...10 V
    Max. load [Ω]
    500
    Min. load [Ω]
    2000
    Pulse output
    flow rate meter
    Measuring / setting range
    Flow monitoring
    Measuring range
    0.00...13.22 gpm
    0...793 gph
    Display range
    0.00...15.86 gpm
    0...951 gph
    Resolution
    0.02 gpm
    1 gph
    Set point, SP
    0.02...13.22 gpm
    1...793 gph
    Reset point, rP
    0.00...13.20 gpm
    0...791 gph
    Analog start point, ASP
    0.00...10.62 gpm
    0...637 gph
    Analog end point, AEP
    2.60...13.22 gpm
    156...793 gph
    in steps of
    0.02 gpm
    1 gph
    Volumetric flow quantity monitoring
    Pulse value
    0.02...9000 * 10³ gal
    in steps of
    0.02 gal
    Pulse length [s]
    0.6...2
    Temperature monitoring
    Measuring range [°F]
    14.0...176.0
    Resolution [°F]
    0.5
    Set point, SP [°F]
    14.0...176.0
    Reset point, rP [°F]
    14.0...176.0
    Analog start point, ASP [°F]
    14.0...144.0
    Analog end point, AEP [°F]
    46.0...176.0
    in steps of [°F]
    0.5
    Accuracy / deviations
    Flow monitoring
    Accuracy
    < ± (3% MW + 0.2% MEW) *) / < ± (5% MW + 0.5% MEW) **)
    Repeatability
    0.025 gpm; 1.5 gph
    Pressure loss (dP) / flow rate (Q)
    Temperature monitoring
    Accuracy [K]
    ± 5.4 (Q > 0.26 gpm)
    Reaction times
    Power-on delay time [s]
    10
    Flow monitoring
    Start-up delay [s]
    0...50
    Response time [s]
    < 0.250 (dAP = 0)
    Damping, dAP [s]
    0.0...1.0
    Temperature monitoring
    Response time [s]
    T09 = 70 (Q > 1 gpm) *)
    Environment
    Ambient temperature [°F]
    14...140
    Storage temperature [°F]
    -13...176
    Protection
    IP 67
    Tests / approvals
    Pressure equipment directive
    article 3, section 3 - sound engineering practice
    EMC
    EN 61000-4-2 ESD:
    4 kV CD / 8 kV AD
    EN 61000-4-3 HF radiated:
    10 V/m
    EN 61000-4-4 Burst:
    2 kV
    EN 61000-4-5 Surge:
    0.5 kV
    EN 61000-4-6 HF conducted:
    10 V
    Shock resistance
    DIN IEC 68-2-27:
    20 g (11 ms)
    Vibration resistance
    DIN IEC 68-2-6:
    5 g (10...2000 Hz)
    MTTF [Years]
    185
    Mechanical data
    Process connection
    G¾ flat seal
    Materials (wetted parts)
    stainless steel 316L / 1.4404; Viton; PES; Centellen 200
    Housing materials
    housing: AlMgSi0.5 anodized; sealing: Viton; connector housing: brass Optalloy-plated; PA 6.6; cover film: polyamide
    Weight [kg]
    1.163
    Displays / operating elements
    Display
    Display unit
    5 x LED green (gpm, gph, gal, °F, 10³)
    Switching status
    2 x LED yellow
    Measured values
    4-digit alphanumeric display
    Programming
    4-digit alphanumeric display
    Electrical connection
    Connection
    M12 connector; gold-plated contacts
    Wiring
    OUT1: 3 selection options
    - switching output volumetric flow monitoring
    - pulse output volumetric flow
    - switching output preset counter
    OUT2/InD: 5 selection options
    - switching output volumetric flow monitoring
    - switching output temperature monitoring
    - analog output volumetric flow
    - analog output temperature
    - input for an external reset signal
    Accessories
    Accessories (included)
    2 x packing washer (Centellen)
    Accessories (optional)
    adapter;
    order no. E40191 (for ½" NPT pipe, high-grade stainless steel);
    order no. E40154 (for ½" NPT pipe, brass)
    Remarks
    Remarks
    ¹) to EN50178, SELV, PELV
    *) for water
    **) for glycol solutions (35%) and oils (viscosity: 68 mm²/s at 40°C)
    MW = measured value
    MEW = final value of the measuring range
    sealing: only with supplied Centellen seals
    Pack quantity [piece]
    1
    ifm efector, inc. • 1100 Atwater Drive • Malvern • PA 19355  —  We reserve the right to make technical alterations without prior notice.  —  US  —  SU7001  —  12.11.2014